The decision depends on both devices, electrical conditions and the operating environment. Communication on a development board alone is insufficient to justify removing isolation. Two CAN ports or independent networks do not automatically provide galvanic isolation. Review signal paths, power paths and any ground connection that crosses the intended barrier.

Selection Checklist

ConditionInformation or Measurement NeededSelection Impact
Ground relationshipsReference grounds, chassis ground, supplies and connectionsGround potential differences and return paths
Component capabilityTransceiver common-mode range, ratings and isolator documentationWhether operating conditions stay within specified limits
Isolation boundarySignal isolation, isolated power, debug ports and other connectionsPossible bridging or bypass of the intended barrier
Site conditionsCable, termination, interference sources, ESD and surge requirementsProtection, layout, connectors and test scope
Product conditionsInstallation, temperature, enclosure, maintenance and applicable requirementsDevelopment board, board revision or custom product hardware

Assess Prototype and Product Conditions Separately

Short communication on a controlled bench demonstrates the tested interaction under those conditions. It does not establish field immunity, safety or long-term operation. Record prototype connections and limits first. Product development then assesses isolated power, interface protection, layout, harness and tests for the intended environment. Hardware changes should follow documented findings.

Which Evidence Is Not Interchangeable?

An isolated transceiver does not establish system safety certification. A dual CAN label does not prove isolation on both channels. Separate CAN buses do not rule out a shared ground path. Isolation ratings in a chip datasheet must not be presented as the result of a whole-product withstand test.

Reference and Project Assessment

TI discusses ground potential differences and electromagnetic compatibility as considerations for isolated CAN in industrial interfaces. The reference identifies assessment factors; isolation ratings, protection parameters and pass criteria still depend on project equipment and design. Without schematics and device conditions, the assessment remains unverified.

References

Questions and Answers

Do two separately connected CAN buses establish galvanic isolation?

No. Independent controllers and communication paths let the two buses be handled separately. Galvanic isolation also requires a review of the transceivers, power, grounding and other connection paths. Two ports or two message-processing paths do not establish isolation.

Does bench communication validate a non-isolated development board for field use?

The bench result covers the grounding, power, cables and interference conditions used. Field use still requires a review of the actual environment, potential differences, interface protection and equipment requirements, followed by project-specific verification. Passing prototype communication does not replace product-interface validation.

What hardware information is needed to assess an isolation approach?

Provide the board schematic and revision, CAN controller and transceiver details, power and grounding paths, connector pinouts, cables and termination, interface protection and expected environment. Review the complete connection against both devices. A component description or architecture diagram alone is not a system isolation test record.